Application Control Application Control

Browse the Fortiguard Labs extensive encyclopedia of applications. Click any title to view more details of the application. Can't find what you are looking for? Try using the search bar above to find a specific application description.

This indicates detection of the ICCP/TASE.2 protocol. ICCP (Inter-Control Center Communications Protocol), also known as TASE.2...

Jan 06, 2009 RISK: POPULARITY:
This indicates detection of an ECHONET Lite "Property value write & read" response (SetGet_Res) for Audiovisual related Class...

Sep 05, 2018 RISK: POPULARITY:
This indicates detection of the Common Industrial Protocol Unconnected Send Get Attributes List command.Common Industrial Protocol...

Jul 10, 2017 RISK: POPULARITY:
This indicates detection of the BACnet Who Has Integer Value command.BACnet is an ASHRAE building automation and control networking...

Sep 20, 2016 RISK: POPULARITY:
This indicates detection of the BACnet Who Has Large Analog Value command.BACnet is an ASHRAE building automation and control...

Sep 20, 2016 RISK: POPULARITY:
This indicates detection of the IEC 61850 GetLogStatusValues command.IEC 61850 is a communication standard for electrical substation...

Sep 16, 2016 RISK: POPULARITY:
This indicates detection of the DNP3 protocol. DNP3 (Distributed Network Protocol) is a set of communication protocols used between...

May 12, 2009 RISK: POPULARITY:
This indicates detection of the Token frame in the FL-net protocol.The FL-net network enables efficient data exchange and communication...

Feb 05, 2019 RISK: POPULARITY:
This indicates detection of an ECHONET Lite "Property value notification" response not possible message (INF_SNA) for Air Conditioning...

Sep 05, 2018 RISK: POPULARITY:
This indicates detection of an ECHONET Lite "Property value write & read" response not possible message (SetGet_SNA) for Housing...

Sep 05, 2018 RISK: POPULARITY:
This indicates detection of the OPC HDA IOPCHDA AsyncUpdate DeleteRaw command.OPC (OLE for process control), currently known as...

Apr 11, 2018 RISK: POPULARITY:
This indicates detection of the OPC HDA IOPCHDA SyncUpdate Replace command.OPC (OLE for process control), currently known as "OPen...

Apr 11, 2018 RISK: POPULARITY:
This indicates detection of the BACnet Who Is command.BACnet is an ASHRAE building automation and control networking protocol.

Sep 12, 2016 RISK: POPULARITY:
This indicates detection of the Modbus protocol.Modbus is a serial communication protocol which is commonly used to connect industrial...

Jan 06, 2009 RISK: POPULARITY:
This indicates detection of an ECHONET Lite "Property value write & read" response (SetGet_Res) for Health related Class Group...

Sep 05, 2018 RISK: POPULARITY: